I have been using the timer for over 3 years now. the other day it just stopped working. The screen went blank. You can not even turn the lights on and off manually. can you suggest something?
↧
VPT24-1P just stopped working
↧
How do I install a timer delay switch on an end of run?
I want to install a LTB02-1LZ countdown timer, but there are only two wires - one black and one white, no red. It is an end of run switch, so the white wire is actually the hot wire and the black runs back to the lights. How do I do it?
↧
↧
LTB60-1LZ 3-Way Wiring
I'm trying to wire up this with the corresponding VP0SR-1LZ. The wiring diagrams match up perfectly for the Remote Switch, but the LTB60 is asking for 5 wires and I only have 4 (including the ground). I've identified the ground, 2nd traveler
↧
VPT24 issue. stopped working few hours after installation
Hi, I just purchased today a VPT24 switch, installed it, got it working. A friend of mine came to see me and few hours later, went to check the nice job I did.... The switch doesn't have lcd anymore, if i press the MENU button
↧
VPT24-1P wiring diagram
I'm trying to hook up my VPT24-1P timer on a three way system. the big problem is on both switches already installed i only have three wires. red, white and black. the ground is in the back of the box but what do i hook up the red/yellow wire too? how
↧
↧
Question on LTB60-1LZ Wiring
Hi: I am trying to install a LTB60-1LZ countdown timer into a 4 gang box. The box is in a bathroom and near a GFCI outlet. The switch I am replacing is a 2 wire, three speed motor control for a fan. The old switch has two black
↧
LTB30 Timer Installation for Bathroom Fan
Hi guys, I purchased a Leviton LTB30 and tried to installed it for my bathroom fan. However I'm confused by my bathroom fan wiring. I'm not sure if this is a 3 way or single pole configuration. This is the existing wiring. 3 sets of wires
↧
Help with VPT23-1P wiring
I am trying to install a VPT24-1P to replace a single pole switch for a light. The box only has 2 wires (one white and one black) plus the ground feeding it. I am not sure how to connect the VPT24 to this - the instructions assume that I have
↧
Low light intensity with Leviton timer
I installed a Leviton timer at home this weekend and all looked good, got everything hooked up and programmed, but when the lights turned on they did not have full intensity, it looked like they only had about 50% of the normal intensity? Any idea what
↧
↧
Wiring LTB60-1LZ does not work, stops other switch
I have a bathroom with a three-switch panel (left: vanity lights, middle: bathroom fan light, right: bathroom fan). I wanted to install a LTB60-1LZ for the fan so I connected it as follows: - Neutral: connected to a wire from the unused bundle of
↧
Can't figure out how to wire VPT24-1PZ with Matching Remote
I am trying to replace two existing 3-pole switches with a Leviton vizia+ (VPT24-1PZ) along with a Matching Switch Remote (VP0SR-1LZ) but have been unsuccessful. I can get the switch screen to power up but it still will not control the light.
↧
Leviton Vizia
Is there any way to keep the screen lit on all the time? -Thanks in advance!
↧
VPT24-1P* Programming Question
Can the VPT24 be programmed in a way that utilizes a plus or minus sunset/sunrise time?
↧
↧
timer switch and GFCI
I bought a 6124H-W electronic timer switch a couple of years ago. I have a circuit that runs from the house to the street with a post light, outlet, and low-voltage transformer feeding some path lights, and wanted to put the lights on a
↧
Help installing VPT24-1P Timer switch
THis is what I am seeing inside my box in the wall - A copper ground wire A black wire A red wire on this new unit I see the following green wire - I am pretty certain this connects to the copper wire in the wall a black
↧
How do I install a timer delay switch on an end of run?
I want to install a LTB02-1LZ countdown timer, but there are only two wires - one black and one white, no red. It is an end of run switch, so the white wire is actually the hot wire and the black runs back to the lights. How do I do it?
↧
Problem when installing VPT24-1P
I am trying to install a Leviton VPT24-1P Digital Timer Switch: Hi I'm trying to install the timer swtich on the right most light switch of a 3-light switch electric box. ----------------------------------------------------- Original box setup: From
↧
↧
Programming the VPT24-1P
I have successfully installed & programmed my VPT24-1P, in PRO mode for automatic turn on at sundown and turnoff at sunup, but the "temporary override when flashing" is flashing. Why and what does that mean? There is no explanation of
↧
VPT24-1PZ, Pro Mode, Sunup/Sundown offset time.
Hi, I installed this timer, and it's working. I have the porch lights come on at 6 am, and off at sunrise, then on at sunset and off at 11 pm. I like it. My question is on what the offset setting is for? Is it used to
↧
VPT24-1PZ Astronomical Program not working
Hello, We've purchased a VPT24-1PZ timer to drive the exterior lights on our building. A picture of the box is below. The installation seems correct. When pressing the toggle cover on the timer switch the lights turn
↧